Banner Maxx II Fungicide can be applied at anywhere from 0.5 – 4 ounces per 1000 sq ft. Not exceeding 4 ounces per 1000 sq ft. Generally speaking, one gallon of mixed solution will treat approx. 1000 sq ft, therefore you can mix 0.5 – 4 ounces into one gallon of water.
It is not recommended to use the Banner Maxx II Fungicide in a hose end applicator as they do not deliver an even application and most do not go down to a low enough setting for proper dilution.
Banner Maxx II Fungicide should not be applied during the heat of the day when there is full sunlight as this is when plants are more stressed and will not absorb the product as readily as during less stressful times. Early morning applications are fine.
Banner Maxx II Fungicide rates vary depending on what you are treating. Please refer to the product label for complete instructions for your specific use.
Banner Maxx II Fungicide does not need to have a surfactant or any type of adjuvant mixed with it per the product label.
Per the Banner Maxx II Fungicide product label you would apply 1-2 fl oz per 1000 sqft at 14-21 day intervals. Begin applications in May or June before disease is present. Tank-mix with a registered contact fungicide labeled for brown patch control at the label rate. Under conditions of high temperatures and high humidity, use the higher rates of Banner MAXX II and shorter intervals.
Banner Maxx Fungicide has been discontinued from the manufacturer and replaced with Banner Maxx II Fungicide. The mix rate is dependent on what disease you are treating. Please refer to Rate Chart on page 9 of the product label.
Banner Maxx II Fungicide does not need to be watered in after application. The application all depends on what you are applying to and treating for. Please be sure to review the Product Label before application. We recommend no rain or irrigation within the first 24 hrs following the application.
If Banner MAXX II is tank-mixed with other products, use the following sequence: 1. Always check the compatibility of the tank mix using a jar test with proportionate amounts of Banner MAXX II, other chemicals to be used, and the water, before mixing in the spray tank. 2. Provide sufficient jet or mechanical agitation during filling and application to keep the tank mix uniformly suspended. 3. Fill tank at least 1/2 full of clean water. 4. Add wettable powders to the tank first, allowing them to completely suspend in the tank before proceeding. This process can be hastened by premixing the product in water before adding to the tank. 5. Add flowables or suspensions next. 6. Add Banner MAXX II next. 7. Add emulsifiable concentrates last. 8. Do not leave tank-mix combinations in the spray tank for prolonged periods without agitation. Mix and apply them the same day.