Ken from Gerald Mo. writes
In order to apply Taurus SC correctly for a termite treatment, you will need to trench 6 inches wide and 6 inches deep along the foundation to apply the product. This insures that you have a continuous barrier without gaps and that the product is deep enough in the soil to effective. Attempting to drill holes in the soil is not a sufficient application. We have more details in our online Subterranean Termite Prevention Guide here.
Answer last updated on: 10/27/2021